| Waveform | On hrss | On Time Difference |
| Gaussian σ=0.3 ms | Measured values of hrss are consistently below injected values, especially for H1 and L1. With the new criteria for εh, they will not be bad calibrations any more, but still needed to be studied. Saturation with higher hrss in early injections can be noticeable, especially with L1. |
Time difference plots of L1 are interesting. |
| Gaussian σ=1 ms | New condition for εh should work for this waveform better. From H2 plots, it is shown that something happened with low hrss injections around 834500000. | H2 plots shows that something happened with low hrss injections around 834500000. |
| Gaussian σ=3 ms | Even if these injections have been good with old criteria, shifts in εh - once (H1 and L1) or twice (H2) during the S5, which is reason of double-peaked distributions for H1 and L1. (Calibration??) | The time difference plots of H1 show that most injections are close to L1 while a few of early injections have the same value as H2. |
| Gaussian &sigma=10 ms | Good | Good |
| Sine Gaussian f=50Hz Q=9 | A couple of bad injections early on H1 and H2 injections. | A couple of bad injections early on H1 and H2 injections. |
| Sine Gaussian f=70Hz Q=9 | H2 shows the similar problem with Gaussian with σ=1ms around 834500000. | H2 shows the similar problem with Gaussian with σ=1ms around 834500000. |
| Sine Gaussian f=100Hz Q=9 | Small shifts are noticeable in H1 and H2 like Gaussian with σ=3ms (above). A couple of bad injections early on H1 and H2. | Good |
| Sine Gaussian f=153Hz Q=9 | A couple of bad injections early on H1 and H2. A small, but noticeable, shift on H1. |
Good |
| Sine Gaussian f=235Hz Q=9 | New condition for εh should work for this waveform better. H2 shows problem around 824500000. | Most bad injections with time measurement are with low hrss injections for all IFOs. H2 problem around 824500000. |
| Sine Gaussian f=393Hz Q=9 | Good | A couple of bad injections early on H1 and H2 - The condition for time difference (30ms) too big?? |
| Sine Gaussian f=554Hz Q=9 | A couple of bad injections early on H1 and H2. | A couple of bad injections early on H1 and H2 |
| Sine Gaussian f=850Hz Q=9 | A couple of bad injections early on H1 and H2 | A couple of bad injections early on H1 and H2. |
| Sine Gaussian f=914Hz Q=9 | New condition for εh should work for this waveform better. H2 has bad injections occasionally including the one around 824500000 - Need to relax the condition for this?? |
Some outliers with H2. |
| Sine Gaussian f=1304Hz Q=9 | A couple of bad injections early on H1 and H2 | A couple of bad injections early on H1 and H2 |
| Sine Gaussian f=2000Hz Q=9 | New condition for εh should work for this waveform better. H2 shows problem around 824500000. | Noisy with low hrss injections for all IFOs. H2 shows problem around 824500000. |
| Sine Gaussian f=3068Hz Q=9 | New condition for εh should work for this waveform better. Early injections with higher hrss(H1, H2, L1) had saturation. A couple of bad injection early on H1 and H2. |
A couple of bad injections early on H1 and H2. |
| Zwerger-Mueller (A3B3G1) | New condition for εh should work for this waveform better. H2 shows problem around 824500000. | Peak time measured is 10 ms after the injected offset time consistently for all IFOs. H2 shows problem around 824500000. |
| Cosmic string cusp fcutoff= 220 Hz | Strength of injections may be too small (Bustset 23), as shown in here for H1 and the same plots from other IFOs are similar. | Noisy - Need to check! |
| Band-Limited White Noise Burst f=250hz δf=100hz σ=30ms | Double peaked distribution of hrss difference as shown in here for H1 and other ifos show the similar distributions too. | Noisy - Need to check!! |
| Ringdown f=2600Hz δt=30ms | H2 shows problem around 824500000. | Noisy with low hrss injections. |